Saxsons Group — India's trusted nuclear medicine, radiotherapy, oncosurgery, dosimetry and cyclotron supplier since 1986
Knowledge Hub · Division

Radiotherapy

Select a product below to explore its clinical evidence library.

RT-006Live

Gold Anchor™ Fiducial Marker

Authorised distribution by Saxsons

22
papers

Folding gold anchor design with zero in-treatment migration across 795 patients and 45+ peer-reviewed publications.

MRI-CompatibleZero MigrationEndoscopic-Ready
0.32%
Migration rate
45+
Publications
95.5%
MRI detection
RT-005Live

Delta4 Phantom+

Authorised distribution by Saxsons

6
papers

Pre-treatment patient-specific QA phantom for IMRT, VMAT and SBRT — the most widely installed QA system worldwide.

IMRT / VMATSBRT QAMR-linac Ready
6
Publications
TG-218
Framework
3D
Dose matrix
RT-008Live

DoseView™ 3D Water Phantom

Authorised distribution by Saxsons

4
papers

3-axis Cartesian water phantom for linac commissioning and annual QA. Four peer-reviewed anchor citations: Akino 2014 (JACMP · lowest 0.08 % inter-variability across 4 tanks), Saenz 2016 (IJCTO · mechanical cross-comparison), Das 2008 (AAPM TG-106 · framework), Narayanasamy 2016 (JACMP · Elekta Versa HD FFF commissioning).

AAPM TG-106TG-142 Annual QAFFF-Ready
4
Publications
0.08 %
inter-variability (Akino 2014)
< 1 %
TG-106 measurement-error target
RT-009Live

QA BeamChecker Plus

Authorised distribution by Saxsons

4
papers

Daily linac QA — 8-chamber ion-chamber array covering all photon + electron energies + FFF up to 2400 MU/min in one cable-free setup. Four peer-reviewed anchor citations: Chan 2015 (IJMPCERO · 5-year Trilogy trending · +0.25 %/month drift), Ma 2021 (JACMP · EPID vs BeamChecker Plus on 6 MV FFF · ±1.1 % agreement), Han 2021 (PLoS One · ion-chamber-array uncertainty budget) and Barnes 2016 (JACMP · vendor MPC benchmark).

AAPM TG-142 / TG-198FFF-ReadyCable-Free
4
Publications
+ 0.25 %/mo
Chan 2015 drift · 5-yr Trilogy
2400 MU/min
max dose rate (FFF)
RT-010Live

MAX 4000 Plus · Reference Electrometer

Authorised distribution by Saxsons

4
papers

Reference-grade electrometer for TG-51 / TG-51 addendum photon + electron reference dosimetry and IAEA TRS-398 absorbed-dose determination. Four peer-reviewed anchor citations: McEwen 2014 (Med Phys · photon addendum), Renaud 2024 (Med Phys · Report 385 electron addendum), McCaw 2017 (JACMP · protocol comparison), Kawashima 2023 (JACMP · P_elec self-inspection).

TG-51 AddendumTRS-398IEC 60731
4
Publications
± 0.1 %
ADCL P_elec agreement
Report 385
2024 electron addendum
RT-011Live

LUCY 3D QA Phantom

Authorised distribution by Saxsons

4
papers

End-to-end stereotactic QA phantom for SRS / SRT / SBRT commissioning + annual QA. Four peer-reviewed anchor citations: Sarkar 2016 (J Radiosurg SBRT · Lucy 3D vs StereoPHAN head-to-head), Halvorsen 2017 (JACMP · AAPM MPPG 9.a practice guideline · 72-hour E2E-phantom requirement), Lim 2022 (JACMP · film vs diode-array E2E QA · γ 94-100 %) and Brown 2022 (JACMP · MLC SRS commissioning criteria · < 1 mm Winston-Lutz + ± 5 % dose + γ > 90 %).

AAPM MPPG 9.aTG-101 / TG-135CT + MRI + CBCT
4
Publications
< 1 mm
W-L iso ↔ target (Brown 2022)
≤ 72 hr
MPPG 9.a availability
RT-016Live

ART Phantom (Alderson RANDO)

Authorised distribution by Saxsons

Anthropomorphic phantom — refined RANDO design, ICRU-44 tissue equivalence, TLD / OSL / MOSFET / ion-chamber compatible.

ICRU-44Male + Female10,000+ Sites
ICRU-44
Tissue eq.
2.5 cm
Slice pitch
TLD/OSL
Dosimetry
RT-023Live

TruPose™ Head Adjuster

Authorised distribution by Saxsons

6DoF head positioning for bore-class linacs — pitch / roll / yaw ±4.0° each; closes the SRS rotational gap without a robotic couch.

SRS / SRT6DoFSGRT-Compatible
±4.0°
Range/axis
3 DoF
Rotational
3.5 kg
Static weight
RT-017Live

Saxsons Fixed Laser Positioning

Saxsons own-brand · Made in India

Saxsons own-brand fixed laser positioning — accelerator / cobalt / simulator / CT-sim iso-centre indication. Semiconductor red 635 nm Class II.

Own-BrandFixed Iso-CentreMade in India
2×+1
Cross + linear
635 nm
Semiconductor
Class II
Laser class
RT-018Live

Saxsons Moving Laser Positioning

Saxsons own-brand · Made in India

Saxsons own-brand movable laser positioning — 1 / 3 / 5-axis configurations on linear guide rails with closed-loop feedback. DICOM RT compatible.

Own-BrandMotorisedDICOM RT
±0.2 mm
Accuracy
5-axis
Movement
DICOM
Integration
RT-019Live

Patient Positioning Solutions

Authorised distribution by Saxsons

5
papers

Modular positioning baseplate family — head/neck/shoulder, thorax, pelvis, breast, full-body + MR-linac variants. Five peer-reviewed anchor citations: Olch 2014 (Med Phys · AAPM TG-176 · 2-4 % baseplate perturbation), Cuccia 2021 (Rad Oncol · MR-Linac positioning · < 1 mm systematic error), Wang 2016 (JACMP · H&N SRT immobilisation · 2.7 → 0.0 mm), Laaksomaa 2024 (Rep Pract Oncol Radiother · multicenter breast DIBH · 150 patients / 2 269 image pairs) and Yan 2013 (JACMP · automatic patient-safety system).

AAPM TG-176 / TG-179MR-Linac ReadyDIBH Breast
5
Publications
< 1 mm
MR-Linac systematic error (Cuccia 2021)
2 – 4 %
TG-176 carbon-fibre perturbation
RT-001 · 002 · 003Live

Thermoplastic Mask Family

Authorised distribution by Saxsons

5
papers

Thermoplastic immobilisation mask family — H&N S-Frame + full-face cranial/SRS + body shell. Five anchor citations: You 2024 (JACMP), Mail 2024 (J Biol Methods), AAPM TG-176, Mangesius 2019 (SRS intrafractional 6D), Cuccia 2021 (MR-linac hybrid).

H&N + SRS + MR-linacAAPM TG-176MR-Compatible
5
Publications
TG-176
Framework
≤ 2 mm
6D setup accuracy
RT-020Live

Vacuum Cushions

Authorised distribution by Saxsons

Vacuum-bag immobilisation for SBRT, H&N IMRT, lung, abdomen, pelvis and whole-body. AAPM TG-101 / TG-178 framework.

TG-101ReusableBody-Region Sizes
TG-101
Framework
S/M/L/XL
Sizes
Polyurethane
Outer
RT-021Live

SBRT Immobilization System

Authorised distribution by Saxsons

Ten-component SBRT immobilisation — couch-indexed platform + belly / knee / wing bridges + T-vacuum cushion + carbon-fibre headrest. AAPM TG-101.

TG-10110 ComponentsUniversal Adapters
10
Components
TG-101
Framework
Universal
Couch adapters
RT-022Live

Breast & Lung Positioning

Authorised distribution by Saxsons

Wing-Board T-Grip, supine + prone breast boards, prone belly cushion. DIBH heart-sparing, breast IMRT, lung tangential. AAPM TG-66.

TG-66DIBH< 2 % Attenuation
TG-66
Framework
DIBH
Heart-sparing
< 2 %
Attenuation