Saxsons™ Foot-Operated Lead-Lined Waste BinLead-Lined Radioactive-Waste Containment with Hands-Free Foot-Pedal Operation
Saxsons own-brand foot-operated waste bin range for safe containment of contaminated solid waste — used syringes, swabs, vials, gloves, lab paper — from the radiopharmacy dispensing workflow. Configurable shielding-tier ladder covers the dispense-energy range across SPECT (Tc-99m), I-131 therapy, routine PET and high-activity PET / Lu-177 theranostic workflows. Shielding on ALL sides including the lid — operator-facing dose-rate stays inside the AERB / ICRP envelope at any standing position. Hands-free foot-pedal operation minimises hand-contamination risk and reduces hand-time over the open bin. Stainless-steel outer chassis with clean-room / GMP-grade finish option. Wheel-mounted variant for mobile high-throughput radiopharmacies. Designed and manufactured in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant. Sign in to view the complete configuration matrix.
Key Features
- Saxsons own-brand product — designed and manufactured in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant
- Lead shielding on ALL sides including the lid — operator-facing dose-rate stays under AERB / ICRP envelope at any standing position around the bin
- Configurable shielding-tier ladder covers the dispense-energy range — routine SPECT (Tc-99m), I-131 / Ga-67 / In-111 work, routine PET (FDG / Ga-68 / Cu-64), high-activity PET and Lu-177 theranostic (PRRT / PSMA-617) workflows
- Multiple chassis-size options — standard footprint through larger footprints for higher per-shift solid-waste production
- Wheel-mounted high-shielding variant — mobile between dispense stations or to the decay-store room; avoids manual lift-carry of a heavy shielded chassis
All Features
- Saxsons own-brand product — designed and manufactured in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant
- Lead shielding on ALL sides including the lid — operator-facing dose-rate stays under AERB / ICRP envelope at any standing position around the bin
- Configurable shielding-tier ladder covers the dispense-energy range — routine SPECT (Tc-99m), I-131 / Ga-67 / In-111 work, routine PET (FDG / Ga-68 / Cu-64), high-activity PET and Lu-177 theranostic (PRRT / PSMA-617) workflows
- Multiple chassis-size options — standard footprint through larger footprints for higher per-shift solid-waste production
- Wheel-mounted high-shielding variant — mobile between dispense stations or to the decay-store room; avoids manual lift-carry of a heavy shielded chassis
- Stainless-steel outer standard; clean-room / GMP-grade decontamination-friendly outer available
- Foot-pedal lid mechanism — hands-free lid open + close; operator drops waste without contact with the lid surface
- Pairs with the Saxsons decay drum range for the decay-store hold step before final biomedical-waste disposal
- Documentation: per-batch lead-thickness certificate, ISO 9001 / ISO 13485 quality records
Technical Specifications
| Brand / build | Saxsons own-brand — manufactured in India by Saxsons Healthcare Pvt. Ltd., ISO 9001 / ISO 13485 approved plant |
| Shielding tiers (all sides + lid) | Configurable shielding-tier ladder spanning SPECT, routine PET, high-activity PET and Lu-177 theranostic workflows — full ladder in the sign-in variant matrix |
| Inner volumes | Configurable inner-volume range per tier — full range in the sign-in variant matrix |
| Chassis sizes | Standard and larger chassis-size options — full range in the sign-in variant matrix |
| Operation | Foot-pedal lid mechanism — hands-free |
| Mobility option | Wheel-mounted variant available on the high-shielding tier |
| Outer material | Stainless steel — standard finish, plus clean-room / GMP-grade finish option |
| Target isotopes | Tc-99m · I-131 · Ga-67 · In-111 · F-18 · Ga-68 · Cu-64 · Lu-177 (theranostic) |
| Compliance framework | AERB Safety Code for Nuclear Medicine Facility · ICRP Publication 103 · Bio-Medical Waste Management Rules (India) · ISO 9001 / ISO 13485 |
| Documentation | Per-batch lead-thickness certificate · ISO quality-record pack |
Applications
Shielding tier matches the radiopharmaceutical class · all-side + lid shielding keeps operator-facing dose-rate inside envelope
Tc-99m SPECT solid waste
Light-shielding tier for routine cardiac / oncology / renal SPECT lists — used syringes, swabs, vial septa go in via the foot-pedal. Operator hand stays clear of the lid throughout.
I-131 thyroid / Ga-67 / In-111
Stepped-up shielding tier for mid-energy gamma — I-131 ablation prep waste, Ga-67 oncology waste, In-111 octreotide waste. Clean-room-grade stainless outer recommended for the daily wipe-down validation cycle.
Routine PET (FDG / Ga-68 / Cu-64)
PET-tier shielding sized per per-shift cumulative activity. The higher tier in the PET range is the right call for hot-labs dispensing 30+ unit doses per shift where cumulative solid-waste activity accumulates measurably.
Lu-177 theranostic-suite waste
High-shielding tier for PRRT / PSMA-617 / FAPI per-patient prep waste. Mobile wheel variant convenient for ferrying the bin between the dispensing bench and the decay-store after the shift.
High-throughput PET radiopharmacy
Highest-shielding tier for radiopharmacies running multi-dose source-vial PET dispensing. Larger-chassis options available for higher per-shift solid-waste volumes.
Decay-store routing
After the shift, lifted-out polybag transfers to the Saxsons decay drum (matched shielding tier) for the half-life-based hold before final biomedical-waste disposal — chain-of-custody documented on the AERB log.
Why Saxsons™ Foot-Operated Lead-Lined Waste Bin?
Unlike a bench-side shield where the operator stands in front, the waste bin is approached from any angle in the hot lab. Lead shielding on the body, base AND lid means the operator-facing dose-rate is bounded regardless of standing position; the AERB / ICRP cumulative-dose envelope holds across the shift.
The hand that just dispensed a radiopharmaceutical may carry trace contamination. A foot-pedal lid means the operator does not touch the lid surface during waste deposit — the hand-to-surface contamination path is broken, and the daily lid-decontamination wipe-down covers any incidental aerosol.
A high-shielding waste bin weighs significantly more than a light-shielding one. The wheel-mounted variant lets the operator move the high-shielding tier between dispense stations or to the decay-store without manual lift-carry — avoiding wrist / back injury risk and keeping the shielding mass where it needs to be.
Catalogs & Resources
AERB Safety Code for Nuclear Medicine Facility
Indian regulatory framework — solid-waste collection, hold, decay and final disposal chain in the hot lab.
Bio-Medical Waste Management Rules — India
CPCB framework for biomedical waste that the radioactive-waste chain inherits at the post-decay step.
IAEA Safety Reports Series No. 38
IAEA guidance for radiation-safety standards in nuclear medicine including solid-waste containment.
Saxsons own-brand · Variant brochure
Request the full Saxsons™ Foot-Operated Lead-Lined Waste Bin variant brochure
The detailed variant matrix, dimensions, accessories and AERB import documentation are not published on this page. Tell us who you are and a Saxsons sales engineer will email the brochure to your institutional address within one working day.
Brochure dispatch is reviewed by a sales engineer before sending — we may verify by phone.
Saxsons™ Foot-Operated Waste Bin
More for this product
Each card opens a focused post for a specific specialty — peer-reviewed evidence and clinical workflow, written for the persona you select.
The Saxsons waste bin, picked for the dispense-cycle close-out
Contact Saxsons Healthcare Pvt. Ltd. for tier + chassis-size + outer-material configuration, wheel-mounted option, ISO documentation and pairing with the Saxsons decay drum and sharps container — designed and manufactured in India.